Authorized IBC dealer

IBC boiler dealer in Pickering — hydronic heating for Toronto & Durham

Climate Experts plans IBC boiler systems for radiator homes, in-floor heating, hydronic air handlers and custom-home projects across Pickering, Durham Region and Toronto. We start with heat loss, water temperatures and zoning so the boiler and the distribution work together.

Ibc SL 14-115 G3 boiler appliance

IBC equipment: compare the system, not just the badge

These manufacturer-published families are a starting point for a proposal. We confirm Canadian distributor availability, the exact model and capacity, and the equipment we recommend for your home before ordering.

SL Series G3

Climate Experts compares the smallest active zone with the boiler’s minimum output, then checks the water temperature needed by radiators, floors or fan coils. For a home that also needs an indirect cylinder, we size the storage and recovery separately and plan how the boiler changes between heating and tank calls.

Read specifications, model data and selection notes
Published technical data
ApplicationHeating boiler; indirect domestic water requires separate tank.
ControlsV-10 touchscreen; outdoor reset; 0–10VDC or 4–20mA control input.
Limited warranty — conditions applyFor post-July2024 manufacture, residential all parts 100% years0–5; heat exchanger 100% years6–10 and25% years11+. Original owner/location, authorized distribution, qualified installation, registration and maintenance conditions; labour excluded. Do not describe lifetime coverage as full replacement for life.
SL 10-85G3
Published technical data
ModelSL 10-85G3
Heating input, minimum–maximum (BTU/h)10600 – 85000
CSA output, minimum–maximum (BTU/h)10100 – 79000
AFUE (%)96
Electrical120VAC/60Hz
Full-fire power without pumps (W)54
SL 14-115G3
Published technical data
ModelSL 14-115G3
Heating input, minimum–maximum (BTU/h)14000 – 115000
CSA output, minimum–maximum (BTU/h)13300 – 109000
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)72
SL 20-160G3
Published technical data
ModelSL 20-160G3
Heating input, minimum–maximum (BTU/h)20000 – 160000
CSA output, minimum–maximum (BTU/h)19000 – 147000
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)82
SL 30-199G3
Published technical data
ModelSL 30-199G3
Heating input, minimum–maximum (BTU/h)32000 – 199000
CSA output, minimum–maximum (BTU/h)30000 – 181300
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)100

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss SL Series G3 with Climate Experts

VX residential boilers

For VX, Climate Experts checks the load of the whole home and of the smallest zone before choosing among the three firing ranges. We also inspect the retained piping and allow access to the heat exchanger, pumps and venting so a compact wall installation remains practical to maintain.

Read specifications, model data and selection notes
Published technical data
ApplicationHeating boiler; separate indirect tank may supply domestic hot water.
ControlsV-10 touchscreen, outdoor reset, four zone pump/valve control plus primary pump; cascade up to four.
Limited warranty — conditions applyResidential: other parts5 years; heat exchanger100% years0–10,25% years11–15. Commercial heat exchanger5 years/other parts2 years. Original owner and location; qualified trained installer; maintenance/water-quality requirements. Labour excluded.
VX110
Published technical data
ModelVX110
Heating input, minimum–maximum (BTU/h)16900 – 110000
CSA output, minimum–maximum (BTU/h)16200 – 101500
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)90
VX150
Published technical data
ModelVX150
Heating input, minimum–maximum (BTU/h)23000 – 150000
CSA output, minimum–maximum (BTU/h)22000 – 138500
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)79
VX199
Published technical data
ModelVX199
Heating input, minimum–maximum (BTU/h)30600 – 199000
CSA output, minimum–maximum (BTU/h)29200 – 183700
AFUE (%)95
Electrical120VAC/60Hz
Full-fire power without pumps (W)90

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss VX residential boilers with Climate Experts

SFC-1 Superflow combi

Climate Experts checks two separate requirements for an SFC combi: the heating load and the hot water used at the same time. We compare the published flow at a realistic winter temperature rise with your fixtures, then review recirculation and whether storage would better suit long or overlapping draws.

Read specifications, model data and selection notes
Published technical data
ControlsTouchscreen, outdoor reset, 0–10VDC input, DHW recirculation pump relay; ECM heating pump packaged with boiler.
Limited warranty — conditions applySingle residential unit: heat exchanger10 years and other parts5 years. Commercial heat exchanger5 years/parts5 years. Original owner/location, qualified installation, normal use and maintenance/water quality apply; labour excluded.
SFC99-1
Published technical data
ModelSFC99-1
Heating input, minimum–maximum (BTU/h)15500 – 99000
Csa heating output BTU/h min max14800 – 89000
Domestic hot-water input, minimum–maximum (BTU/h)15500 – 99000
AFUE (%)96
Domestic hot water US gpm at 67F 37 2C rise2.4
Electrical120VAC/60Hz;120W full fire including internal pump
SFC125-1
Published technical data
ModelSFC125-1
Heating input, minimum–maximum (BTU/h)16500 – 99000
Csa heating output BTU/h min max15800 – 89000
Domestic hot-water input, minimum–maximum (BTU/h)16500 – 125000
AFUE (%)95
Domestic hot water US gpm at 67F 37 2C rise3.2
Electrical120VAC/60Hz;120W full fire including internal pump
SFC199-1
Published technical data
ModelSFC199-1
Heating input, minimum–maximum (BTU/h)28500 – 125000
Csa heating output BTU/h min max27100 – 111000
Domestic hot-water input, minimum–maximum (BTU/h)28500 – 199000
AFUE (%)95
Domestic hot water US gpm at 67F 37 2C rise5.0
Electrical120VAC/60Hz;120W full fire including internal pump

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss SFC-1 Superflow combi with Climate Experts

EBX electric boilers

Climate Experts checks the available electrical service and supply voltage before selecting EBX. The same model delivers less heat at208V than at240V; we compare that available output with the heat loss and planned water temperature, and size any heat-pump backup arrangement around the actual shortfall.

Read specifications, model data and selection notes
Published technical data
ControlsSetpoint or outdoor reset; built-in three-speed pump; dual titanium elements.
Limited warranty — conditions applyResidential pump/elements1 year, other parts5 years; commercial1 year. Original owner/location; licensed trained contractor; electrical and water-quality conditions apply. Labour excluded.
EBX 4K-240
Published technical data
ModelEBX 4K-240
Modulating power kW at240V min max0.4 – 4
Modulating power kW at208V min max0.3 – 3
Max current A at240V with pump17.6
Published breaker A30
Electrical noteFinal conductor/protection installation follows selected manual and applicable code.
EBX 8K-240
Published technical data
ModelEBX 8K-240
Modulating power kW at240V min max0.8 – 8
Modulating power kW at208V min max0.6 – 6
Max current A at240V with pump34.2
Published breaker A45
Electrical noteFinal conductor/protection installation follows selected manual and applicable code.
EBX 10K-240
Published technical data
ModelEBX 10K-240
Modulating power kW at240V min max1 – 10
Modulating power kW at208V min max0.8 – 7.5
Max current A at240V with pump42.6
Published breaker A60
Electrical noteFinal conductor/protection installation follows selected manual and applicable code.
EBX 12K-240
Published technical data
ModelEBX 12K-240
Modulating power kW at240V min max1.2 – 12
Modulating power kW at208V min max0.9 – 9
Max current A at240V with pump50.9
Published breaker A70
Electrical noteFinal conductor/protection installation follows selected manual and applicable code.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss EBX electric boilers with Climate Experts

Published ratings apply to particular models and test conditions. Your Climate Experts proposal identifies the selected equipment and installation requirements; we confirm the applicable Canadian specifications before ordering.

Choosing IBC for your home

IBC boilers support projects where the distribution system matters as much as the boiler itself: cast-iron radiators, in-floor heating, hydronic air handlers and snow melt. In Toronto renovations, we assess the retained piping and emitters before choosing the new heat source. A large boiler is not a substitute for a balanced system.

For a custom home, we plan zones, water temperatures, controls and domestic hot water together. An electric boiler requires an electrical-capacity review; a gas boiler requires suitable fuel and venting arrangements. We explain the system options before mechanical drawings are finalized, including how service access and future maintenance will work.

Before equipment is ordered

We review the heating and cooling requirements, installation access and service space. The written proposal names the equipment, controls and agreed work.

When the installation is complete

We commission the system, explain the controls and maintenance, and document the applicable registration and warranty details.

IBC warranty: parts, equipment and labour

Coverage depends on the exact equipment, Canadian certificate, installation and registration. Parts, heat exchangers, equipment replacement and labour are separate benefits. Read the family-specific terms above; our written proposal identifies the coverage for your selected system.

Current IBC offers and rebate planning

Manufacturer promotions change by model, location and dealer participation. Ask us to check any current Canadian offer against your exact system and purchase date; we show confirmed eligibility and expiry dates in the written proposal.

For heat-pump projects, review Ontario rebate planning before purchase. Program eligibility is separate from a manufacturer promotion.

Manufacturer information checked October 5, 2026.

Your IBC system, supported by a local team

Pickering roots. Toronto and Durham service.

Climate Experts was founded by Cody Johnson in 2012. Cody brings 20 years of HVAC experience, with G2, 313D and 308R licences. Our shop is at Unit 13, 905 Dillingham Rd, Pickering. Office hours are Monday–Friday, 8 a.m.–5 p.m., with emergency service evenings and weekends.

Explore our team, our work and customer reviews.

Equipment information from your local team

Stay with Climate Experts while you compare the equipment. We explain the proposed models, installation scope and maintenance, and provide the applicable product and warranty documents for your selected system.

Ask Climate Experts for the equipment details

Boiler systems
Radiant hydronic heating
Custom-home HVAC consulting

IBC questions homeowners ask

Can one IBC boiler serve radiators and in-floor heating?

Potentially, with a design that supplies the water temperatures and flow each circuit needs. We plan zone controls, pumps and any mixing arrangement around the emitters.

Why does the boiler’s minimum output matter?

When one small zone calls for heat, an oversized minimum output can cause short cycling. We compare the boiler’s modulation range with the smallest likely heating demand.

Is an EBX electric boiler the same as an air-to-water heat pump?

No. EBX is electric resistance heating. A heat pump moves heat and has different efficiency, output and installation requirements. We compare electrical capacity and running-cost assumptions before selecting an all-electric approach.

Can you review the hydronic design before my renovation drawings are final?

Yes. Early consulting covers mechanical space, zones, piping, domestic hot water, controls and service access, helping the system fit the building and budget.

What is included in a IBC installation quote?

The quote identifies the selected equipment and controls, installation scope, applicable warranty and any confirmed rebates. Tell us about comfort problems, planned renovations and access restrictions so those needs can be assessed before the scope is agreed.

Can you maintain my IBC system after installation?

Contact our Pickering service team for maintenance planning. The visit and schedule depend on the equipment, its condition and the manufacturer’s requirements. Maintenance 365 options can be reviewed with the specific systems you want covered.

Talk to a Climate Expert about IBC

Tell us where you live, what equipment you have and what you want to improve. We will discuss the assessment and system options for your home.