Daikin Comfort Pro

Daikin Comfort Pro in Pickering & Toronto — FIT heat pumps, furnaces & ductless

Climate Experts is a Daikin Comfort Pro serving Pickering, Durham Region and Toronto. We plan compact Daikin FIT systems, furnace replacements and ductless heating and cooling around the rooms you use, the space outside your home and the comfort you want through an Ontario winter.

Daikin FIT R-32 outdoor heat pump unit

Daikin equipment: compare the system, not just the badge

These manufacturer-published families are a starting point for a proposal. We confirm Canadian distributor availability, the exact model and capacity, and the equipment we recommend for your home before ordering.

Daikin FIT DH6VS / DH7VS / DH9VS Aurora

For a Toronto side yard, Climate Experts checks the cabinet against service access, snow accumulation and the distance to neighbouring windows. We then compare the heat available from the proposed indoor and outdoor match at the home’s design temperature, so the backup heat decision follows the load calculation.

Read specifications, model data and selection notes
Published technical data
Family efficiency limits
DH6VS
Up to 19 SEER2 / 8.8 HSPF2
DH7VS
Up to 19 SEER2 / 8.8 HSPF2
DH9VS
Up to 21 SEER2 / 10 HSPF2
Basis
Family maxima for specific tested combinations; HSPF2 region is not explicitly labelled on cover. No per-model efficiency assigned.
ControlsDaikin One+ and compatible Daikin communicating indoor equipment; confirm the selected indoor/outdoor combination and controller in the installation manual. Two low-voltage wires connect the outdoor unit in communicating mode.
Limited warranty — conditions applyManufacturer limited coverage, not labour: listed FIT sheets describe 12-year parts and unit replacement after online registration within 60 days in Ontario; unit replacement also requires annual maintenance. Other exclusions apply; obtain the exact Canadian certificate. Quebec registration exemptions do not apply to an Ontario installation.
DH6VSA1810A
Published technical data
ModelDH6VSA1810A
Capacity
Nominal size (tons)
1.5
Cooling capacity at 95°F (BTU/h)
17100
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
12.8
Maximum overcurrent protection (A)
15
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA2410A
Published technical data
ModelDH6VSA2410A
Capacity
Nominal size (tons)
2.0
Cooling capacity at 95°F (BTU/h)
23200
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
16.8
Maximum overcurrent protection (A)
20
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA3010A
Published technical data
ModelDH6VSA3010A
Capacity
Nominal size (tons)
2.5
Cooling capacity at 95°F (BTU/h)
28400
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
22.4
Maximum overcurrent protection (A)
25
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA3610A
Published technical data
ModelDH6VSA3610A
Capacity
Nominal size (tons)
3.0
Cooling capacity at 95°F (BTU/h)
34200
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
22.4
Maximum overcurrent protection (A)
25
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA4210A
Published technical data
ModelDH6VSA4210A
Capacity
Nominal size (tons)
3.5
Cooling capacity at 95°F (BTU/h)
41000
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
31.8
Maximum overcurrent protection (A)
35
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA4810A
Published technical data
ModelDH6VSA4810A
Capacity
Nominal size (tons)
4.0
Cooling capacity at 95°F (BTU/h)
45500
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
31.8
Maximum overcurrent protection (A)
35
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH6VSA6010A
Published technical data
ModelDH6VSA6010A
Capacity
Nominal size (tons)
5.0
Cooling capacity at 95°F (BTU/h)
53500
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
37.5
Maximum overcurrent protection (A)
40
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH7VSA2410A
Published technical data
ModelDH7VSA2410A
Capacity
Nominal size (tons)
2.0
Cooling capacity at 95°F (BTU/h)
23200
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
27-3/8 × 36-5/8 × 13-3/4
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
22.4
Maximum overcurrent protection (A)
25
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH7VSA3610A
Published technical data
ModelDH7VSA3610A
Capacity
Nominal size (tons)
3.0
Cooling capacity at 95°F (BTU/h)
35000
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
31.8
Maximum overcurrent protection (A)
35
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH7VSA4210A
Published technical data
ModelDH7VSA4210A
Capacity
Nominal size (tons)
3.5
Cooling capacity at 95°F (BTU/h)
41000
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
37.5
Maximum overcurrent protection (A)
40
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH7VSA4810A
Published technical data
ModelDH7VSA4810A
Capacity
Nominal size (tons)
4.0
Cooling capacity at 95°F (BTU/h)
46500
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
37.5
Maximum overcurrent protection (A)
40
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH7VSA6010A
Published technical data
ModelDH7VSA6010A
Capacity
Nominal size (tons)
5.0
Cooling capacity at 95°F (BTU/h)
52000
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
56-5/16 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
34.4
Maximum overcurrent protection (A)
40
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH9VSA241CA
Published technical data
ModelDH9VSA241CA
Capacity
Nominal size (tons)
2.0
Cooling capacity at 95°F (BTU/h)
24000
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
56-5/16 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
17.4
Maximum overcurrent protection (A)
20
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DH9VSA361CA
Published technical data
ModelDH9VSA361CA
Capacity
Nominal size (tons)
3.0
Cooling capacity at 95°F (BTU/h)
34200
Basis
Outdoor product specification, AHRI 210/240; exact indoor match still required for system performance.
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
56-5/16 × 37 × 12-5/8
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
21.8
Maximum overcurrent protection (A)
25
Scope
Outdoor only; verify unit rating plate.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss Daikin FIT DH6VS / DH7VS / DH9VS Aurora with Climate Experts

Daikin FIT DC6VS air conditioner

Climate Experts considers FIT cooling when a narrow equipment location makes a conventional outdoor unit awkward. Our proposal pairs the condenser with the coil and blower that establish its rating, then checks airflow, drain routing and the sound expected at the nearby property line.

Read specifications, model data and selection notes
Published technical data
Family efficiency limitsUp to 17.2 SEER2; a family ceiling, not a rating for every model. Exact AHRI indoor match required.
ControlsDaikin One+ and compatible Daikin communicating indoor equipment; confirm the selected indoor/outdoor combination and controller in the installation manual. Two low-voltage wires connect the outdoor unit in communicating mode.
Model id noteAsterisk is the published revision wildcard, not an orderable serial number. Page 3 shortens the 5T prefix while page 39 dimensions explicitly shows DC6VSS6010A*; verify the complete ordered suffix. The document also covers DC6VSA…WA alternatives; no Ontario availability inferred.
Limited warranty — conditions applyManufacturer limited coverage, not labour: listed FIT sheets describe 12-year parts and unit replacement after online registration within 60 days in Ontario; unit replacement also requires annual maintenance. Other exclusions apply; obtain the exact Canadian certificate. Quebec registration exemptions do not apply to an Ontario installation.
DC6VSS1810A*
Published technical data
ModelDC6VSS1810A*
Capacity
Nominal size (tons)
1.5
Max cooling BTU/h
17100
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
27-3/8 × 36-5/8 × 13-3/4
Sound
Pressure dBA at 3ft zero reflective surfaces
54
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
12.8
Maximum overcurrent protection (A)
15
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS2410A*
Published technical data
ModelDC6VSS2410A*
Capacity
Nominal size (tons)
2.0
Max cooling BTU/h
23200
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
27-3/8 × 36-5/8 × 13-3/4
Sound
Pressure dBA at 3ft zero reflective surfaces
57
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
16.8
Maximum overcurrent protection (A)
20
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS3010A*
Published technical data
ModelDC6VSS3010A*
Capacity
Nominal size (tons)
2.5
Max cooling BTU/h
28400
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
27-3/8 × 36-5/8 × 13-3/4
Sound
Pressure dBA at 3ft zero reflective surfaces
60
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
22.4
Maximum overcurrent protection (A)
25
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS3610A*
Published technical data
ModelDC6VSS3610A*
Capacity
Nominal size (tons)
3.0
Max cooling BTU/h
34200
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
27-3/8 × 36-5/8 × 13-3/4
Sound
Pressure dBA at 3ft zero reflective surfaces
61
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
22.4
Maximum overcurrent protection (A)
25
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS4210A*
Published technical data
ModelDC6VSS4210A*
Capacity
Nominal size (tons)
3.5
Max cooling BTU/h
41000
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
Sound
Pressure dBA at 3ft zero reflective surfaces
64
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
31.8
Maximum overcurrent protection (A)
35
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS4810A*
Published technical data
ModelDC6VSS4810A*
Capacity
Nominal size (tons)
4.0
Max cooling BTU/h
45500
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
Sound
Pressure dBA at 3ft zero reflective surfaces
65
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
31.8
Maximum overcurrent protection (A)
35
Cold weather capacityNot applicable: cooling-only air conditioner.
DC6VSS6010A*
Published technical data
ModelDC6VSS6010A*
Capacity
Nominal size (tons)
5.0
Max cooling BTU/h
53500
EfficiencyUnavailable: not verified for this exact model/matched system in the reviewed sources.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
39 × 37 × 12-5/8
Sound
Pressure dBA at 3ft zero reflective surfaces
66
Basis
Cooling standard mode, AHRI 275; this is not quiet-mode sound power.
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
37.5
Maximum overcurrent protection (A)
40
Cold weather capacityNot applicable: cooling-only air conditioner.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss Daikin FIT DC6VS air conditioner with Climate Experts

DR97MC / DR96TC / DR96TN furnaces

When replacing a Durham furnace, Climate Experts measures the heat requirement and checks return air, venting and available installation space before selecting a cabinet. We explain how the modulating DR97MC, communicating two-stage DR96TC and nine-speed two-stage DR96TN affect operation and the controls included in the quote.

Read specifications, model data and selection notes
Published technical data
ControlsDR97MC and DR96TC are communicating variable-speed families. DR96TN uses a two-stage gas valve and nine-speed ECM. Exact thermostat wiring and matched FIT capability must follow the selected installation manual.
Limited warranty — conditions applyOntario product pages describe lifetime heat exchanger, 12-year parts and six-year unit replacement with registration within 60 days; annual maintenance conditions apply to replacement. Verify the exact Canadian certificate; labour is separate.
DR97MC0603BN
Published technical data
ModelDR97MC0603BN
Capacity
High fire input BTU/h
60000
High fire output BTU/h
58200
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
8.1
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR97MC0803BN
Published technical data
ModelDR97MC0803BN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
77600
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
8.1
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR97MC0804CN
Published technical data
ModelDR97MC0804CN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
77600
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
11.4
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR97MC1005CN
Published technical data
ModelDR97MC1005CN
Capacity
High fire input BTU/h
100000
High fire output BTU/h
97000
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
14.4
Maximum overcurrent protection (A)
25
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR97MC1205DN
Published technical data
ModelDR97MC1205DN
Capacity
High fire input BTU/h
120000
High fire output BTU/h
116400
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
14.4
Maximum overcurrent protection (A)
25
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC0403BN
Published technical data
ModelDR96TC0403BN
Capacity
High fire input BTU/h
40000
High fire output BTU/h
39000
Fuel
Natural gas
Efficiency
AFUE (%)
97.5
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.5
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC0603BN
Published technical data
ModelDR96TC0603BN
Capacity
High fire input BTU/h
60000
High fire output BTU/h
58200
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.5
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC0803BN
Published technical data
ModelDR96TC0803BN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
76880
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.5
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC0804CN
Published technical data
ModelDR96TC0804CN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
77600
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
10.8
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC1005CN
Published technical data
ModelDR96TC1005CN
Capacity
High fire input BTU/h
100000
High fire output BTU/h
96100
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
13.8
Maximum overcurrent protection (A)
20
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC1005DN
Published technical data
ModelDR96TC1005DN
Capacity
High fire input BTU/h
100000
High fire output BTU/h
97500
Fuel
Natural gas
Efficiency
AFUE (%)
97.5
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
13.8
Maximum overcurrent protection (A)
20
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TC1205DN
Published technical data
ModelDR96TC1205DN
Capacity
High fire input BTU/h
120000
High fire output BTU/h
115320
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
13.8
Maximum overcurrent protection (A)
20
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0303AN
Published technical data
ModelDR96TN0303AN
Capacity
High fire input BTU/h
30000
High fire output BTU/h
29100
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.8
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0403AN
Published technical data
ModelDR96TN0403AN
Capacity
High fire input BTU/h
40000
High fire output BTU/h
38800
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.8
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0603AN
Published technical data
ModelDR96TN0603AN
Capacity
High fire input BTU/h
60000
High fire output BTU/h
57660
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.8
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0603BN
Published technical data
ModelDR96TN0603BN
Capacity
High fire input BTU/h
60000
High fire output BTU/h
58200
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.7
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0803BN
Published technical data
ModelDR96TN0803BN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
76880
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
7.7
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN0804CN
Published technical data
ModelDR96TN0804CN
Capacity
High fire input BTU/h
80000
High fire output BTU/h
77600
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
11.3
Maximum overcurrent protection (A)
15
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN1004CN
Published technical data
ModelDR96TN1004CN
Capacity
High fire input BTU/h
100000
High fire output BTU/h
97000
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
14.3
Maximum overcurrent protection (A)
25
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN1005CN
Published technical data
ModelDR96TN1005CN
Capacity
High fire input BTU/h
100000
High fire output BTU/h
97000
Fuel
Natural gas
Efficiency
AFUE (%)
97
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
14.3
Maximum overcurrent protection (A)
25
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.
DR96TN1205DN
Published technical data
ModelDR96TN1205DN
Capacity
High fire input BTU/h
120000
High fire output BTU/h
115320
Fuel
Natural gas
Efficiency
AFUE (%)
96.1
Basis
DOE AFUE, Isolated Combustion System (ICS)
RefrigerantNot applicable to gas furnace itself; separate coil may contain refrigerant.
Dimensions — retain the stated orderUnavailable: not verified for this exact model/matched system in the reviewed sources.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
115
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
14.3
Maximum overcurrent protection (A)
25
Cold weather capacityNot a heat-pump temperature rating; gas input derating and installation conditions apply.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss DR97MC / DR96TC / DR96TN furnaces with Climate Experts

ATMOSPHERA ductless

For an addition or upstairs room, Climate Experts assesses a single ATMOSPHERA zone around the room’s own load and the direction of its airflow. We plan a drain route that can be maintained and a pipe path that fits the building, then identify whether the proposed system supplements existing heat or carries the room through winter.

Read specifications, model data and selection notes
Published technical data
ControlsOntario product page lists built-in Wi-Fi with Daikin Comfort Control App; exact wired/remote controller accessories require the selected manual.
Limited warranty — conditions applyDuctless warranty differs from FIT. Ontario page lists 12-year limited parts, conditional registration within 60 days; obtain the ATMOSPHERA-specific Canadian warranty. Do not import FIT unit-replacement coverage.
FTXM09WVJU9 / RXM09WVJU9
Published technical data
ModelFTXM09WVJU9 / RXM09WVJU9
Capacity
Rated cooling BTU/h
9000
Rated heating BTU/h at 47F
11000
Basis
Cooling indoor 80°F DB/67°F WB, outdoor 95°F DB/75°F WB; heating indoor 70°F DB/60°F WB, outdoor 47°F DB/43°F WB; 25-ft piping.
Efficiency
SEER2
27.4
HSPF2
11.2
EER2
16.3
Region
HSPF2 region not explicitly labelled in reviewed table.
RefrigerantR-32
Dimensions — retain the stated order
Indoor H W D mm
299 × 920 × 275
Outdoor H W D mm
595 × 845 × 300
Sound
Indoor cooling pressure dBA H M L SL
  • 43
  • 33
  • 25
  • 22
Outdoor cooling pressure dBA H
47
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Maximum overcurrent protection (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
FTXM12WVJU9 / RXM12WVJU9
Published technical data
ModelFTXM12WVJU9 / RXM12WVJU9
Capacity
Rated cooling BTU/h
12000
Rated heating BTU/h at 47F
13600
Basis
Cooling indoor 80°F DB/67°F WB, outdoor 95°F DB/75°F WB; heating indoor 70°F DB/60°F WB, outdoor 47°F DB/43°F WB; 25-ft piping.
Efficiency
SEER2
25.2
HSPF2
10.7
EER2
13.2
Region
HSPF2 region not explicitly labelled in reviewed table.
RefrigerantR-32
Dimensions — retain the stated order
Indoor H W D mm
299 × 920 × 275
Outdoor H W D mm
595 × 845 × 300
Sound
Indoor cooling pressure dBA H M L SL
  • 45
  • 37
  • 29
  • 23
Outdoor cooling pressure dBA H
49
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Maximum overcurrent protection (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
FTXM18WVJU9 / RXM18WVJU9
Published technical data
ModelFTXM18WVJU9 / RXM18WVJU9
Capacity
Rated cooling BTU/h
18000
Rated heating BTU/h at 47F
21600
Basis
Cooling indoor 80°F DB/67°F WB, outdoor 95°F DB/75°F WB; heating indoor 70°F DB/60°F WB, outdoor 47°F DB/43°F WB; 25-ft piping.
Efficiency
SEER2
22.7
HSPF2
10
EER2
12.5
Region
HSPF2 region not explicitly labelled in reviewed table.
RefrigerantR-32
Dimensions — retain the stated order
Indoor H W D mm
299 × 1100 × 275
Outdoor H W D mm
735 × 870 × 320
Sound
Indoor cooling pressure dBA H M L SL
  • 49
  • 41
  • 36
  • 33
Outdoor cooling pressure dBA H
54
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Maximum overcurrent protection (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
FTXM24WVJU9 / RXM24WVJU9
Published technical data
ModelFTXM24WVJU9 / RXM24WVJU9
Capacity
Rated cooling BTU/h
21600
Rated heating BTU/h at 47F
24000
Basis
Cooling indoor 80°F DB/67°F WB, outdoor 95°F DB/75°F WB; heating indoor 70°F DB/60°F WB, outdoor 47°F DB/43°F WB; 25-ft piping.
Efficiency
SEER2
22
HSPF2
10
EER2
12
Region
HSPF2 region not explicitly labelled in reviewed table.
RefrigerantR-32
Dimensions — retain the stated order
Indoor H W D mm
299 × 1100 × 275
Outdoor H W D mm
735 × 870 × 320
Sound
Indoor cooling pressure dBA H M L SL
  • 51
  • 44
  • 37
  • 34
Outdoor cooling pressure dBA H
55
Electrical
Voltage (V)
208–230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Maximum overcurrent protection (A)
Unavailable: not verified for this exact model/matched system in the reviewed sources.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss ATMOSPHERA ductless with Climate Experts

DFVE R-32 air handler

In an all-electric conversion, Climate Experts checks the DFVE blower against the duct pressure and the space available for service. We identify the outdoor match and any accessory electric heater separately, because the backup heat choice changes both the electrical work and the winter heating plan.

Read specifications, model data and selection notes
Published technical data
ControlsDaikin One+ and compatible Daikin communicating indoor equipment; confirm the selected indoor/outdoor combination and controller in the installation manual. Two low-voltage wires connect the outdoor unit in communicating mode.
Limited warranty — conditions applyCurrent sheet describes 12-year parts after Ontario registration within 60 days; obtain exact certificate. Air handler has no gas heat exchanger: do not reuse furnace heat-exchanger warranty text.
DFVE24BP1300
Published technical data
ModelDFVE24BP1300
Capacity
Nominal size (tons)
2
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
45 × 17-1/2 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
4.9
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DFVE36CP1300
Published technical data
ModelDFVE36CP1300
Capacity
Nominal size (tons)
3
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
53-7/16 × 21 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
6.5
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DFVE42CP1300
Published technical data
ModelDFVE42CP1300
Capacity
Nominal size (tons)
3.5
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
53-7/16 × 21 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
6.5
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DFVE48CP1300
Published technical data
ModelDFVE48CP1300
Capacity
Nominal size (tons)
4
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
58 × 21 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
6.5
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DFVE48DP1300
Published technical data
ModelDFVE48DP1300
Capacity
Nominal size (tons)
4
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
53-7/16 × 24-1/2 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
6.5
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.
DFVE60DP1300
Published technical data
ModelDFVE60DP1300
Capacity
Nominal size (tons)
5
Scope
Air-handler nominal size; not a complete system rating.
EfficiencyNo standalone SEER2/HSPF2. Requires matched outdoor unit.
RefrigerantR-32
Dimensions — retain the stated order
H W D (inches)
58 × 24-1/2 × 21
Basis
Page 4 drawing: A height, C cabinet width, side-view 21-inch cabinet depth; excludes projections.
SoundUnavailable: not verified for this exact model/matched system in the reviewed sources.
Electrical
Voltage (V)
208/230
Phase
1
Frequency (Hz)
60
Minimum circuit ampacity (A)
8.6
Maximum overcurrent protection (A)
15
Scope
Base air handler without field-installed heater. Heater kits change circuit requirements.
Cold weather capacityUnavailable: not verified for this exact model/matched system in the reviewed sources.

Manufacturer documentation reviewed October 20, 2026. Exact Canadian availability, production suffix and installation requirements are confirmed with your proposal.

Discuss DFVE R-32 air handler with Climate Experts

Maximum efficiency ratings apply to specific tested combinations. Your proposal identifies the matched indoor and outdoor equipment; an operating-temperature limit does not guarantee full heating capacity at that temperature.

Choosing Daikin for your home

Daikin FIT is particularly useful when outdoor space matters. In Toronto side yards, additions and renovations, the equipment location needs to work with access, windows, snow and neighbouring properties. We plan the indoor and outdoor equipment together, rather than choosing a condenser first and trying to make the rest fit afterward.

A Daikin furnace and FIT heat pump can form a dual-fuel system; an appropriate air handler can support an all-electric design. Ductless equipment addresses a different need: room-by-room heating and cooling where adding full ductwork would be disruptive. We compare those approaches with your existing boiler or furnace, room layout, electrical capacity and comfort goals.

Before equipment is ordered

We review the heating and cooling requirements, installation access and service space. The written proposal names the equipment, controls and agreed work.

When the installation is complete

We commission the system, explain the controls and maintenance, and document the applicable registration and warranty details.

Daikin warranty: parts, equipment and labour

Coverage depends on the exact equipment, Canadian certificate, installation and registration. Parts, heat exchangers, equipment replacement and labour are separate benefits. Read the family-specific terms above; our written proposal identifies the coverage for your selected system.

Current Daikin offers and rebate planning

Canadian Daikin FIT instant rebates

For eligible complete R-32 FIT systems purchased October 1–December 31, 2026: DH9VS (Aurora), $1,400 CAD; DH7VS, $1,050 CAD; DC6VS / DH6VS, $700 CAD.

Available through participating Daikin Comfort Pros. A qualifying complete system and controller are required. Cannot be combined with other offers, discounts or promotions. Confirm our participation and your equipment’s eligibility before purchase.

Have us confirm the offer and eligibility

For heat-pump projects, review Ontario rebate planning before purchase. Program eligibility is separate from a manufacturer promotion.

Manufacturer information checked October 5, 2026.

Your Daikin system, supported by a local team

Pickering roots. Toronto and Durham service.

Climate Experts was founded by Cody Johnson in 2012. Cody brings 20 years of HVAC experience, with G2, 313D and 308R licences. Our shop is at Unit 13, 905 Dillingham Rd, Pickering. Office hours are Monday–Friday, 8 a.m.–5 p.m., with emergency service evenings and weekends.

Explore our team, our work and customer reviews.

Equipment information from your local team

Stay with Climate Experts while you compare the equipment. We explain the proposed models, installation scope and maintenance, and provide the applicable product and warranty documents for your selected system.

Speak with our local Daikin team

Daikin heat-pump installation
Ductless design and installation
All-electric heating

Daikin questions homeowners ask

Is Daikin FIT suitable for a narrow Toronto side yard?

Its compact side-discharge design is useful where a traditional outdoor unit is bulky. We still check the exact manufacturer clearances, snow exposure, windows, service access and neighbouring property before selecting the location.

Should I choose a FIT heat pump or FIT air conditioner?

A heat pump provides heating as well as cooling. A FIT air conditioner provides cooling while the furnace handles heating. We compare your fuel choices, electrical capacity and winter heating needs.

Does every FIT system qualify for the advertised rebate?

No. The current manufacturer offer applies to eligible complete R-32 FIT systems through participating Comfort Pros. The model combination, purchase date and participation must be checked before the rebate is included in your quote.

Can I control the system remotely?

Compatible Daikin One controls offer connected operation. We explain thermostat compatibility and any optional remote monitoring or dealer diagnostic access before setup.

What is included in a Daikin installation quote?

The quote identifies the selected equipment and controls, installation scope, applicable warranty and any confirmed rebates. Tell us about comfort problems, planned renovations and access restrictions so those needs can be assessed before the scope is agreed.

Can you maintain my Daikin system after installation?

Contact our Pickering service team for maintenance planning. The visit and schedule depend on the equipment, its condition and the manufacturer’s requirements. Maintenance 365 options can be reviewed with the specific systems you want covered.

Talk to a Climate Expert about Daikin

Tell us where you live, what equipment you have and what you want to improve. We will discuss the assessment and system options for your home.